Slide 10 of 13
Notes:
- Along the walls where the existing floor joists are parallel to the new foundation and cripple wall, the same concept of a continuous member applies.
- As shown in Elevation D, the end joist must be a single piece that extends the full length of the new foundation and continues at least to the next perpendicular girder line beyond the end of the new foundation, where it may be spliced as shown in the Detail G.